S24-51522 S24-59718 S24-59970 S24-59974 S24-59907 S24-59972 S24-59976 Park Denis T7b Cartridge Kits

Product Details
Customization: Available
After-sales Service: 1 Year
Warranty: 1 Year
Gold Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
to see all verified strength labels (16)
  • S24-51522 S24-59718 S24-59970 S24-59974 S24-59907 S24-59972 S24-59976 Park Denis T7b Cartridge Kits
  • S24-51522 S24-59718 S24-59970 S24-59974 S24-59907 S24-59972 S24-59976 Park Denis T7b Cartridge Kits
  • S24-51522 S24-59718 S24-59970 S24-59974 S24-59907 S24-59972 S24-59976 Park Denis T7b Cartridge Kits
  • S24-51522 S24-59718 S24-59970 S24-59974 S24-59907 S24-59972 S24-59976 Park Denis T7b Cartridge Kits
  • S24-51522 S24-59718 S24-59970 S24-59974 S24-59907 S24-59972 S24-59976 Park Denis T7b Cartridge Kits
  • S24-51522 S24-59718 S24-59970 S24-59974 S24-59907 S24-59972 S24-59976 Park Denis T7b Cartridge Kits
Find Similar Products

Basic Info.

Model NO.
S24-51522 S24-59718 S24-59970 S24-59974 S24-59907
Acting Form
Single-Acting
Type
Vane Pump
Displacement
Fixed
Certification
ISO
Condition
New
Transport Package
Plywood Case
Specification
32*30*45
Trademark
Hydvic
Origin
Original or China
HS Code
8413910000
Production Capacity
100 Pieces/Week

Product Description

S24-51522 S24-59718 S24-59970 S24-59974 S24-59907 S24-59972 S24-59976 Park Denis T7b Cartridge Kits
S24-51522 S24-59718 S24-59970 S24-59974 S24-59907 S24-59972 S24-59976 Park Denis T7b Cartridge Kits
S24-51522 S24-59718 S24-59970 S24-59974 S24-59907 S24-59972 S24-59976 Park Denis T7b Cartridge KitsS24-51522 S24-59718 S24-59970 S24-59974 S24-59907 S24-59972 S24-59976 Park Denis T7b Cartridge KitsS24-51522 S24-59718 S24-59970 S24-59974 S24-59907 S24-59972 S24-59976 Park Denis T7b Cartridge KitsS24-51522 S24-59718 S24-59970 S24-59974 S24-59907 S24-59972 S24-59976 Park Denis T7b Cartridge Kits
S24-50150 S24-50151 S24-58084 S24-58085 S24-50616 S24-50617 S24-51519
S24-51520 S24-59715 S24-59716 S24-50152 S24-50153 S24-58086
S24-58087 S24-50618 S24-50619 S24-51521 S24-51522 S24-59717 S24-59718 S24-59970
S24-59971 S24-59974 S24-59975 S24-59907 S24-59908 S24-59972 S24-59973 S24-59976
S24-59977 S24-50154 S24-50155 S24-58088 S24-58089 S24-50620 S24-50621 S24-51523
S24-51524 S24-59719 S24-59720
1. Parker Denison pump T6 Single Vane Pump Cartridge Kits, Replacement Denison T6c T6cm T6d T6dm T6e T6em T7e T7em T7b Cartridge
2. Model T6E, T6ER, T7ERS, T6ERM T7ES, T6EM T7ES, T7BS T7E T7ES T7DS T7DRS,
T6C, T6CM T6CR T6CRM T6CRM T6CR,
T6D, T6DM  T6DR, T6DMY T6DRMY T6DRM          
3. Interchangeable Vane Pump cartridge displacement as follow:
    T6C vane pump: 003, 005, 006, 008, 010, 012, 014, 017, 020, 022, 025, 028, 031
    T6D vane pump: 014, 017, 020, 024, 028, 031, 035,038, 042, 045, 050
    T6E vane pump: 042, 045, 050, 052, 057, 062, 066, 072, 085
    T7E vane pump: 042, 045, 050, 052, 057, 062, 066, 072, 085  
4. Feature below. 
The high pressure vane pump incorporates the design of vane pin holdout.
They are applicable for those hydraulic machineries that demand high rotation pressure and low noise level.
The vane pump series are designed for applications in die casting machines, injection molding machines and other special construction equipments.

Hydraulic fluid: Before starting project planning, please refer to our data sheets RE 90220 (mineral oil), RE 90221 (environmentally acceptable hydraulic fluids) and RE 90223 (HF hydraulic fluids) for detailed information regarding the choice of hydraulic fluid and application conditions.

The correct choice of hydraulic fluid requires knowledge of the operating temperature in relation to the ambient temperature: in an open circuit the tank temperature. The hydraulic fluid should be chosen so that the operating viscosity in the operating temperature range is within the optimum range - the shaded area of the selection diagram. We recommended that the higher viscosity class be selected in each case. Example: At an ambient temperature of X°F (X°C) an operating temperature of 140°F (60°C) is set. In the optimum operating viscosity range (shaded area) this corresponds to the viscosity classes VG 46 or VG 68; to be selected: VG 68.Please note: The case drain temperature, which is affected by pressure and speed, is always higher than the tank temperature. At no point in the system may the temperature be higher than 240°C (115°C) for sizes 5 to 200 or 195°F (90°C) for sizes 250 to 500.If the above conditions cannot be maintained due to extreme operating parameters, we recommend flushing the case at port U (size 250 to 500).

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier